Installation - Omega Engineering FTB100 Series User Manual

Liquid turbine flowmeters
Table of Contents

Advertisement

5. Installation

Inspect all packages for any indications of damage which may have
occurred during shipment.
Verify that all meter parts or auxiliary components have arrived with
the shipment. Refer to the packing list/invoice for a detailed list of
items included in the shipment.
The flowmeter may be installed horizontally or vertically for liquid
service without affecting the meter calibration.
It is required to install meter with a minimum straight run of pipe
approximately 10 pipe diameters ahead of the inlet and 5 pipe
diameters following the outlet.
The meter housing is marked by a flow direction arrow and the inlet is
marked 'IN' and the outlet is marked 'OUT'. The meter must be
installed in the piping in the correct orientation to ensure the most
accurate operation.
Install meter with adequate distance and isolation from electric motors,
transformers, welding equipment and solenoids to avoid any
electromagnetic interference from ambient electrical field.