Exciting Amperage; Resistance Value - Kubota GL14000-USA Service Manual

Diesel engine generator
Table of Contents

Advertisement

Exciting Amperage

(1)
Amperage fluctuates based upon the winding temperature. Following is for reference
only
.
Frequency/Rated Output
Single-Phase 60Hz: 12 kW

Resistance Value

(2)
Nominal resistance of the winding is tolerated
temperature. The resistance must be measured by low resistance tester. It cannot be
measured by multi-purpose tester due to index error.
Main Stator
1
Armature
Between
U-W
0.14Ω
(B)
(W)
Black
White
No load
Full load
( power factor=1.0)
Exciter Stator
2
3
Exciter
J-K
Winding
A – B
B – C
C – D
0.29Ω
5.8Ω
(R)
(G)
(Y)
Red
Green
Yellow
Load
within
± 10% at 20℃ of the ambient
Measurement value (Ω)
4
Exciter Field
-
-
8.60Ω
(Br)
(L)
Brown
Blue
13
Exciting Amperage
(Measured)
1.1A
1.5A
Rotor
5
Armature
-
0.83Ω
(Or)
(Gr)
Orange
Gray
(Vi)
Violet

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D902-e4b

Table of Contents