Download Print this page

Dyna-Glo HeatAround HA1360RH User's Manual And Operating Instructions page 10

Radiant heater
Hide thumbs Also See for HeatAround HA1360RH:

Advertisement

TROUBLESHOOTING
PROBLEM
Burner backfiring
during combustion.
High yellow flame
during burner
combustion
Gas odor during
combustion.
Heater produces a
clicking/ticking noise
just after burner is lit
or shut off.
Heater shuts off in
use (ODS operates).
Gas odor exists
even when control
knob is in OFF posi-
tion.
Moisture/conden-
sation noticed on
windows.
Slight smoke or odor
during initial opera-
tion
POSSIBLE CAUSE
1. Burner orifice is clogged or
damaged.
2. Burner is damaged.
3. Gas regulator is damaged.
1. Not enough air.
2. Gas regulator is defective.
3. Outside temperature is too
low.
1. Foreign matter between
control valve and burner.
2. Gas leak. (See Warning
Statement on page 2).
1. Metal is expanding while
heating or contracting
while cooling.
1. Not enough fresh air is
available.
2. Low line pressure.
3. ODS/pilot is partially
clogged.
1. Gas leak. See Warning
Statement on page 2.
2. Control valve is
defective.
1. Not enough combustion/
ventilation air.
1. Residues from
manufacturing process.
CORRECTIVE ACTION
1. Clean burner orifice (see Care and
Maintenance, page 8 or contact
customer service.
2. Contact dealer or customer service.
3. Replace gas regulator.
1. Check burner for dirt and debris. If found,
clean burner (see Care and Maintenance,
page 8).
2. Replace gas regulator.
3. Buy new tank or refill 20lb tank.
1. Take apart gas tubing and remove foreign
matter.
2. Locate and correct all leaks.
1. This is common with most heaters. If
noise is excessive, contact qualified
service technician.
1. Open window and/or door for
ventilation.
2. Contact local gas supplier.
3. Clean ODS/pilot (see Care and
Maintenance, page 8).
1. Locate and correct all leaks (see
"Checking Gas Connections" page 4).
2. Contact customer service.
1. Refer to "Air for Combustion and
Ventilation" requirements, page 4.
1. Problem will stop after a few hours of
operation.
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
10

Advertisement

loading