INSTALLER MENU (C0ntinued)
Installer Menu #
(Hold Menu 8 Seconds)
79
81
83
88
99
TEST EQUIPMENT
Turn on power to the system.
Fan Operation
If your system does not have a G terminal connection, skip to Heating System.
1.) Press the fan button to select the On position. The blower should begin to operate.
2.) Press the fan button to select the Auto position. The blower should stop immediately.
Heating System
1.) Press the System button to select the Heat position. Heat Pumps only - if the auxiliary
heating system has a standing pilot, be sure to light it.
2.) Press
to adjust thermostat setting to 1° above room temperature. The heating system
should begin to operate and the thermostat will indicate Heat On.
3.) For heat pumps with auxiliary- Press
temperature. The auxiliary heat should begin to operate and the thermostat will indicate
Heat On Aux.
4.) Press
to adjust thermostat setting 1° below room temperature. The heating system
should stop operating and the Heat On icon will disappear.
Auxiliary System ( only for heat pumps with auxiliary)
1.) Press the system button to select the Aux position. This bypasses the heat pump and runs
auxiliary only heat.
2.) Press
to adjust thermostat setting to 1° above room temperature. The auxiliary heating
system should begin to operate and the thermostat will indicate Heat On Aux.
3.) Press
to adjust thermostat setting 1° below room temperature. The auxiliary heating
system should stop operating and the Heat On Aux icon will disappear.
Cooling System
1.) Press the System button to select the Cool position.
2.) Press
to adjust thermostat setting 1° below room temperature. The blower should
come on immediately on high speed, followed by cold air circulation. The thermostat will
indicate Cool On. There can be up to a 5 minute delay. (see INSTALLER MENU, item 50)
3.) Press
to adjust thermostat setting to 1° above room temperature. The cooling system
should stop operating and the Cool On icon will disappear.
Note: If Starting Soon is shown on the display, the compressor lockout feature is operating. There will be up
to a 5 minute delay before the compressor turns on (see INSTALLER MENU, item 50).
4
Description
Fahrenheit or Celsius
Temperature Display Adjustment:
adjust the displayed "Room
Temperature"
Continuous Display Light: keep the
backlight always on – "C" wire required
Auto Changeover: thermostat
automatically switches between heat
and cool
Keypad Lock: prevent unwanted
changes to the thermostat
Default Setting
(flashing icons)
OFF
OFF
OFF
to adjust thermostat setting to 3° above room
Settings
(Press
or
°F – Fahrenheit
°F
°C – Celsius
0
-5 to +5
On – always on
OFF – momentarily
On – enable auto
OFF – disable auto
On – disable buttons
OFF – all buttons are active
)