INSTALLER MENU

To prevent changes that may affect system performance, this thermostat has an INSTALLER
MENU and a USER MENU. The INSTALLER MENU provides access to every option, while the
USER MENU provides access to items that will not affect system performance. To access the
INSTALLER MENU press the Menu button for 8 seconds. The display will show item 05 in the
table below. Use Next and Back to navigate through menu items. Press
menu setting.
Installer Menu #
(Hold Menu 8 Seconds)
05
10
15
20
25
30
32
35
50
65
66
Description
Outdoor Equipment: selects air
conditioner (AC) or heat pump (HP)
equipment as well as the number of stage
Indoor Equipment: selects whether the
equipment is a gas furnace, electric furnace
or fan only
Dedicated Emergency: W/E only operates
in Emergency Aux mode. W2 becomes 1st
stage Aux. Heat
O,B or 3 Wire Zone Valve Selection
Circulation Fan Mode: Allows user to set
fan circulation time when equipment has
not cycled for 1hr.
Heat Cycle Rate: how often
heat will turn on
Aux Cycle Rate: how often the auxiliary
heat will turn on
Cool Cycle Rate: how often
cooling will turn on
Compressor Lockout:
protects the compressor
short cycling
Max Heat Limit: maximum set point for
heat mode
Minimum Cool Limit: minimum set point
for cool mode
RC/RH Jumper Wire
This thermostat electrically connects
the RC and RH terminals so a jumper
wire is not required. If the application
provides a separate wire for RC and
RH, clip the RC/RH jumper. This will
isolate both terminals so they can be
independently used.
Battery Location
Premium AA alkaline batteries are
required when C-wire is not available.
When C-wire is available, the batteries
provide a back-up source of power
(this will maintain the clock in the
event of a power outage).
Default Setting
(flashing icons)
AC2
EL2
OFF
O
OFF
the
MEd
MEd
the
MEd
from
OFF
99
45
or
to change a
Settings
(Press
or
)
AC0
AC1
AC2
HP1
FAN
GA1
GA2 (conventional only)
EL1
EL2 (conventional only)
On
OFF
O
B
3
10 minutes to 100 minutes
in 5 minute increments
SLO – slow
MEd – medium
FAS – fast
SLO – slow
MEd – medium
FAS – fast
SLO – slow
MEd – medium
FAS – fast
On – 5 minute delay
OFF – no delay
47 to 99
45 to 97
3