Kenwood TK-8108H Service Manual page 31

Table of Contents

Advertisement

Test Frequency (MHz)
Channel
TX
1 : Center
470.100
2 : Low
450.100
3 : High
489.900
4
470.000
5
470.200
6
470.400
PCB Section
Item
Condition
1. Setting
1) Power supply voltage
DC Power supply terminal : 13.6V
2. VCO lock
1) CH : TX high
voltage*
2) CH : RX high
3) CH : TX low
4) CH : RX low
3. IF coil
1) CH : RX center (Wide)
2) SSG output : –53dBm (501µV)
Mod : 1kHz
Dev : 3kHz
4. RF
1) CH : RX center (Wide)
bandpass
CH : RX low (Wide)
filter
CH : RX high (Wide)
2) Tra generator output : –30dBm
Connect the spectrum analyzer
to BPF terminal
* Adjustment of TX VCO lock voltage
1. Remove R525, R823, R536 and R822 (all on component side).
2. Remove PCB from chassis.
3. Transmit and check voltage at [CV] point.
Warning : Do not transmit if step "1." is not complete.
4. Adjust of voltage can be done by tuning TC402.
ADJUSTMENT
RX
470.050
450.050
489.950
470.000
470.200
470.400
Measurement
Test equipment
Digital voltmeter
SSG
Digital voltmeter
Tra generator
Spectrum analyzer
Adjustment
Terminal
Parts
Method
CV
TC402
5.5V
TC401
5.5V
Check
AFV
L301
3.25~3.35V (DC)
ANT
TC352
Adjust the BPF waveform
BPF
TC353
to Fig. 1
TK-8108H
Specifications/
Remarks
± 0.1V
± 0.1V
0.7V or more
Fig. 1
31

Advertisement

Table of Contents
loading

Table of Contents