INSTALLATION OPTIONS

Read this entire manual before you install and use your pellet
stove. Failure to follow instructions may result in property
damage, bodily injury, or even death! See specific installation
details for clearances and other installation requirements.
Freestanding Unit - supported by pedestal/legs and placed
on a non-combustible floor surface in compliance with
clearance requirements for a freestanding stove installation.
Your pellet stove may be installed to code in either a
conventional or mobile home (see "Special Mobile Home
Requirements"). It is recommended that only a authorized
technician install your pellet stove, preferably an NFI
certified specialist. DO NOT CONNECT THIS UNIT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM. The use of other components
other than stated herein could cause bodily harm, heater
damage, and void your warranty.
IMPROPER INSTALLATION
The manufacturer will not be held responsible for damage
caused by the malfunction of a stove due to improper
venting or installation. Call (800) 750-2723 and/or consult a
professional installer if you have any questions.
CLEARANCES
Your pellet stove has been tested and listed for installation
in residential, mobile home in accordance with the
clearances given below. For safety reasons, please adhere
to the installation clearances and restrictions. Any reduction
in clearance to combustibles may only be done by means
approved by a regulatory authority.

FLOOR PROTECTION

This heater must have a non-combustible floor protector (UL1618 ember protection) installed beneath it if the
floor is of combustible material. US: Floor protector should be UL listed or equal too, needs to extend 6" to the
front, 6" to each side, 1" to the rear of the unit. Under and 2" beyond each side of the cleanout tee if an interior
vertical installation.
Canada: Floor protector should comply with CAN/ULC standards. Needs to extend 18" to the front, 8" beyond
each side of the unit.
Installation
-4-
A
Side Wall to Stove
B
Side Wall to Vent Pipe
C
Back Wall to Stove
D
Back Wall to Vent Pipe
E
Ceiling to Floor
F
Ceiling to Stove
G
Side Wall to Stove
H
Side Wall to Vent Pipe
J
Back Wall to Vent Pipe
FLOOR PROTECTOR CLEARANCES
K
Back to Stove
L
Side to Stove
M Front to Stove
N
Back to Flue
in
mm
10
254
11.5
292
11.88
302
3
76
84
2134
53.88 1434
7.5
191
11.25
286
3
73
in
mm
U.S.A
1
26
CAN
8
204
U.S.A
6
153
CAN
8
204
U.S.A
6
153
CAN
8
204
2
51