Maintenance Schedule; Troubleshooting Guide - United States Stove VOGELZANG VG5501S Manual

Table of Contents

Advertisement

MAINTENANCE SCHEDULE

Use the following as a guide under average use conditions. Gaskets around door and door glass should be
inspected and repaired or replaced when necessary.
Burn Pot
Combustion Chamber
Ashes
Interior Chambers
Combustion Blower Blades
Convection Blower Impeller
Vent System
Gaskets
Glass
Hopper (end of season)
When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money
by enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors:
1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You
can usually solve those problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5. Refer
to diagrams on page 25 to help locate indicated parts.
For the sake of troubleshooting and using this guide to assist you, you should look at your heat level setting to see
which light is flashing.
• Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to "OFF"
does not disconnect all power to the electrical components of the stove.
• Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All
other work should be done by a trained technician.
Display is Flashing "E1"
Possible Causes
The convection blower is overheating and tripping the
internal temperature shutoff.
The stove is being left on the highest setting for
extended periods of time.
Fuel other than wood pellets is being burned in the
stove.
Power surge or brown out situation.
High Limit Switch is malfunctioning.
ATTENTION: This wood heater needs periodic inspection and repair for proper operation. It is against federal
regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.
Daily
Stirred
Wiped
Trouble Shooting Guide
-15-
Weekly
Monthly or as needed
Empty
Brushed
Check
Vacuumed
Vacuumed / Brushed
Vacuumed / Brushed
Cleaned
Empty and vacuumed
Possible Remedies: (Unplug stove first when possible)
Clean any dust off of the windings and fan blade. If
oiling the blower does not help, the blower may be
bad.
If operating the heater on the highest heat setting, the
room temperature could increase enough and lead
to potential overheating situations. If this happens try
operating at a lower heat setting.
This pellet stove is designed and tested to use wood
pellets. Check for signs of fuel other than wood pellets.
No other types of fuel have been approved for this
pellet stove. If there are signs of other types of fuel
being used, stop using them immediately.
A power surge, spike, or voltage drop could cause the
high limit switch to trip. Check to see if a surge protector
is being used on the stove. If not, recommend one to
the customer.
If the other items check out OK, replace the high limit
switch.
Empty
Cleaned
Inspected

Advertisement