Introduction; Specifications - Empire Heating Systems DVC55SPPXLP-1 Installation Instructions And Owner's Manual

Fan type direct vent wall furnace
Table of Contents

Advertisement

Available languages

Available languages

Introduction

always consult your local Building Department regarding regula-
tions, codes or ordinances which apply to the installation of a direct
vent wall furnace.
Instructions to Installer
1.
Installer must leave instruction manual with owner after instal-
lation.
2. Installer must have owner fill out and mail warranty card sup-
plied with furnace.
3.
Installer should show owner how to start and operate furnace.
Warning:
Any change to this furnace or its control can be dangerous.
This is a heating appliance and any panel, door or guard
removed for servicing an appliance must be replaced prior
to operating the appliance.
To Conserve Gas: Turn off pilot when heater is not in use.
General Information
This furnace is design certified in accordance with A merican National
Standard/CSA Standard Z21.86 and CSA 2.32 by the Canadian
Standards Association, as a fan type direct vent wall furnace to be
installed according to these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
All correspondence should refer to complete Model No., Serial No.
and type of gas.
Notice: During initial firing of this unit, its paint will bake out and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the unit is installed.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material other than wood flooring the appliance shall
be installed on a metal or wood panel extending the full width and
depth of the appliance.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is for rugs that are extremely
thick and light colored tile.
Model
Input BTU/HR
Height
Width
Depth
Gas Inlet
CFM
Accessories
SOR-1
SOK-1
DV-822
Page 6
INTRODUCTION
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed
so that all burners and burner ignition devices are located not less
than 18" above the floor.
Such equipment shall be located, or protected, so it is not subject
to physical damage by a moving vehicle.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip-
ment or accessories and repair and servicing of equipment shall
be performed only by a qualified agency. The term "qualified
agency" means any individual, firm, corporation or company which
either in person or through a representative is engaged in and is
responsible for (a) the installation or replacement of gas piping or
(b) the connection, installation, repair or servicing of equipment, who
is experienced in such work, familiar with all precautions required
and has complied with all the requirements of the authority having
jurisdiction.
State of Massachusetts: The installation must be made
by a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
The installation must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA
54* Natural Gas and Propane Installation Code, CSA B149.1.
*Available from the American National Standards Institute, Inc., 11
West 42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet, input ratings should be
reduced at the rate of 4 percent for each 1,000 feet above sea level.
Canadian High Altitudes for locations having an elevation above
mean sea level between 2,000 feet (610m) and 4,500 feet (1370m),
the manifold pressure is to be decreased from 4.0" w.c. to 3.2" w.c.
for Natural Gas and from 10.0" w.c. to 8.0" w.c. for Propane Gas.
Piezo Pilot Ignitor Instructions
Depressing the red button completely causes a spark to occur at
the pilot. This is a substitute for a match which requires opening
the pilot hole cover.
To light the pilot, it is important that the electrode be 1/8" from the
thermocouple. The spark must occur at the point the burner flame
hits the thermocouple. The end of the electrode will be red hot with
the pilot on.
On a new installation with air in the gas line, it is suggested that a
match be used. The match will light the pilot faster than the piezo
under this condition.

SPECIFICATIONS

DV-55SPP
55,000
82 3/8"
16"
11 1/2"
1/2" Pipe
400
Register Side Outlet
Side Outlet Kit, 10" Boot Assembly with Register
Vinyl Siding Vent Kit
32188-0-0616

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvc55sppxnat-1

Table of Contents