Viessmann Vitodens 222-F Installation And Service Instructions For Contractors page 69

Gas condensing storage combi boiler natural gas and lpg version
Table of Contents

Advertisement

General
(cont.)
"Display conditions, parameter"
Setting
For technical services department
For technical services department
"Operation enabled/disabled"
Setting
Everything operable
Everything disabled apart from emissions
test function
Default display and emissions test function
operable
"Time constant for calculating the adjusted outside temperature"
Setting
128 x 10 minutes
... x 10 minutes
"SCOT correction factor, flue length"
Setting
...
"Extension OpenTherm"
Setting
Without
With
"Vitocom 100 GSM"
Setting
Without
With
"Minimum burner output"
Setting
...
"LON communication module: outside temperature"
Setting
Control unit uses outside temperature sen-
sor
Control unit receives outside temperature
Control unit transmits outside temperature
Explanations
8A:175
8A:176
Explanations
8F:0
Controls on the display
8F:1
8F:2
Explanations
90:128
Time constant for calculating the adjusted outside
temperature 21.3 h
90:1 to
Subject to the set value, the flow temperature is adjus-
90:199
ted quickly (low values) or slowly (high values) when
the outside temperature changes
1 step
10 min
Explanations
93:...
Never adjust
Explanations
94:0
94:1
Automatic recognition
Explanations
95:0
Never adjust.
95:1
Explanations
96:...
Factory setting according to boiler-specific parameters
96:... to
Minimum burner output adjustable from ... to 100 %
96:100
Explanations
97:0
Temperature value of the outside temperature sensor
connected to the control unit is utilised
97:1
97:2
Parameter level 2
69