10.4.3 Sensor Application 1/2

PaGE 52
© 2015 OJ Electronics A/S
This option allows you to choose which sensor is used to control the heating
system.
• Floor:
With this setting, the floor sensor controls the heating system.
• Room/Floor Protection: With this setting, the room sensor controls the heating
system while the floor sensor limits heating according to the
temperature limits set under Menu/Installer Settings/Floor Protection.
• Room:
W ith this setting, the room sensor built into the thermostat controls
the heating system.
Note! Floor Protection is not active while using the Sensor Application
"Room".
Note that certain menu options will be grayed out and inaccessible as
they are only applicable with the floor sensor.
• Regulator: W ith this setting, the thermostat operates as a regulator and no
sensors are used. The setting is a percentage of the full load in steps
of 10%.
Note that Floor Protection is not active when using the thermostat as
a regulator.
Floor limit temperatures are set under menu/Installer settings/floor Protection.
Note that changes made under "Sensor Application" do not influence the "Floor
Protection" settings.
<