Modulating boiler control with bacnet communication option
Table of Contents

Advertisement

OBJ ID
OBJECT NAME
900
LOCK00 through LOCK19
through919
1000
LSTHOLD
1100
MAN00 through MAN19
through1119
1200
MAXSTG
1300
MIN
1400
MODE00 through MODE19
through1419
1500
MODST00 through
through1519
MODST19
1600
MTRIM00 through
through1619
MTRIM19
1700
ODTEMP
1800
ODTRIM
1900
OFF
2000
PDATE
2100
PTIME
2200
R
2300
RTMODE
2400
RTTIME
2500
SB
2600
SETPT
2700
SRUNON
2800
STBYDLY
2900
STONOFF00 through
through2919
STONOFF19
3000
STPCT00 through
through3019
STPCT19
3100
SYSONOFF
3200
SYSSEN
3300
TARG
*
AV=analog value(2),
BV=binary value(5),
MV=multi-state value(19).
Note:
The device object id is set through the menus. The device object name is 'WM_' followed by the panel serial number.
Note:
All objects with multiple UOM's depend upon the value of INMODE to determine which to use. Objects with only °F/°C
UOM's default to °F when INMODE is not temperature.
Note:
OFF, R and TARG have no effect unless INMODE is set to Reset °F or Reset °C.
Note:
When writing to MAN, MODE will change to Manual.
BSC Installation and Operation Manual
DESCRIPTION
TYPE*
Lockout Input
Last-Stage-Hold
Manual Modulation Level
Maximum Stages
Minimum Target
Stage Mode
Modulation Start Point
Modulation Output Trim
Outdoor Sensor
Outdoor Sensor Trim
Offset Temp
Panel Date
Panel Time
Reset Ratio
Lead Stage Rotation
Mode
Periodic Rotation Interval
Setback
Set point
System Run-on
Standby Delay
Stage Relay
Modulation Level
System Relay
System Sensor
Calculated Target
UOM
MV
Psi (56), °C(62),
AV
°F(64)
AV
%(98)
AV
none (95)
AV
°C(62), °F(64)
1=Auto, 2=Standby, 3=Manual,
MV
AV
%(98)
AV
none (95)
AV
°C(62), °F(64)
AV
°C(62), °F(64)
AV
°C(62), °F(64)
Days (70) since
AV
1/1/1981
Minutes(72) since
AV
0:00
1=1:4, 2=1:3, 3=1:2, 4=1:1.5,
MV
8=1.5:1, 9=2:1, 10=3:1, 11=4:1
MV
1=Manual, 2=Time, 3=Last-On
AV
Hours(71)
Psi (56), °C(62),
AV
°F(64)
Psi (56), °C(62),
AV
0-100psi, -40 - +122°C, -40 -
°F(64)
AV
Minutes(72)
AV
Minutes(72)
BV
AV
%(98)
BV
Psi (56), °C(62),
AV
0 - 100psi, -40 - +122°C,-40 -
°F(64)
AV
°C(62), °F(64)
RANGE / STATES
1=(inactive),
2=Lockout,3=Comm Error
0 - 3.0psi, 0 - 30psi °C °F
0 - 100
4 - 20
21 - 68°C, 70 - 180°F
4=Off, 5=On
0 - 99
-1.0 - +1.0
-40 - +122°C, -40 - +250°F
-5 - +5
-28 - +28°C, -50 - +50°F
0 - 2,147,483,647
0 - 1439
5=1:1.25, 6=1:1, 7=1.25:1,
1 - 999
0 - 7.5psi, 0 - 75psi °C °F
0.0-15.0psi, 0.0-30.0psi,
+250°F,
0 - 60
1 - 60
0=Off, 1=On
0 - 100
0=Off, 1=On
0.0 - 15.0psi, 0.0 - 30.0psi,
+250°F,
21 - 122°C, 70 - 250°F
READ
ONLY
X
X
X
X
X
X
X
X
29