KVM over IP User Manual
4. Key in the email address of where the report is being sent from in the
From field.
Note:
1. Only one email address is allowed in the From field, and it
cannot exceed 64 Bytes.
2. 1 Byte = 1 English alphanumeric character.
5. Key in the email address (addresses) of where you want the SMTP
reports sent to in the To field.
Note: If you are sending the report to more than one email address,
separate the addresses with a semicolon. The total cannot exceed
256 Bytes.
 Log Server
Important transactions that occur on the KVM over IP switch, such as
logins and internal status messages, are kept in an automatically generated
log file.
 Specify the MAC address of the computer that the Log Server runs on
in the MAC address field.
 Specify the port used by the computer that the Log Server runs on to
listen for log details in the Port field. The valid port range is 1–65535.
The default port number is 9001.
Note: The port number must different than the one used for the Program
port (see Program, page 175).
See Chapter 13, The Log Server, for details on setting up the log server.
The Log File is discussed on page 205.
 SNMP Trap
To be notified of SNMP trap events, do the following:
1. Check Enable SNMP Agent.
2. Key in either the IPv4 address, IPv6 address, or domain name of the
computer to be notified of SNMP trap events.
3. Key in the port number. The valid port range is 1–65535.