Remote Control A-B Selection; Concern About The Operating Noise; Troubleshooting - Toshiba 24J2KCVRG-T Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

REMOTE CONTROL A-B SELECTION

To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the pencil. "00" will be shown on the display. (Picture 1)
4. Press
during pushing
(Picture 2)
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from factory is A.
1
CONCERN ABOUT THE OPERATING
NOISE
Start the operation smoothly and reduce the operating noise.
Quiet
Quiet

TROUBLESHOOTING

(CHECK POINT)
The unit does not operate.
The power main switch is turned off.
The circuit breaker is activated to cut off the power supply.
Stoppage of electric current
ON timer is set.
31
1120650256-00_S02_182x257_68p_S_p70_190110.indd 32
."B" will show on the display and "00" will disappear and the air conditioner will turn OFF. The Remote Control B is memorized.
2
Press for 20 seconds
OPERATION /
RESET Button
Cooling starts after 10 seconds with a "Pi" sound. However, continue to press it.
Setting completes when the "Pi" sounds 5 times and the operation lamp blinks.
To cancel it, repeat the above operation (in this case, the operation lamp does not blink)
Cooling or Heating is abnormally low.
The filters are blocked with dust.
The temperature has been set improperly.
The windows or doors are opened.
The air inlet or outlet of the outdoor unit is blocked.
The fan speed is too low.
The operation mode is FAN or DRY.
POWER SELECTION function is s et 75% or 50% (This function is depend on
remote controller).
2/23/2019 11:33:42 AM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-1824j2acvrg-t

Table of Contents