SELF CLEANING OPERATION (COOL AND
14
DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
button is pressed once during "Cool" or "Dry" mode,
the fan will continue to run for other 20 minutes, then it will turn off
automatically. This will reduce the moisture in the indoor unit.
2. To stop the unit immediately, press the
30 seconds.
OPERATION AND PERFORMANCE
15
1. Three-minute protection feature: To prevent the unit from being activated for
3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before blowing warm
air.
3. Warm air control: When the room temperature reaches the set temperature,
the fan speed is automatically reduced and the outdoor unit will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoor and released into the room.
When the outdoor temperature is too low, use another recommended
heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or other
seasonal debris.
7. Some minor cracking sound may occur when unit operating. This is normal
because the cracking sound may be caused by expansion/contraction of
plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Outdoor Temperature
Operation
Heating
Cooling
Dry
TSB 1110655140_EN_RU.indb 3
TSB 1110655140_EN_RU.indb 3
more 2 times within
Room Temperature
–10°C ~ 24°C
Less than 27°C
21°C ~ 52°C
21°C ~ 32°C
19°C ~ 52°C
17°C ~ 32°C
16

TROUBLESHOOTING (CHECK POINT)

The unit does not operate.
• The power main switch is turned
off.
• The circuit breaker is activated to
cut off the power supply.
• Stoppage of electric current.
• ON timer is set.

REMOTE CONTROL A-B SELECTION

17
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
button on the Remote Control by the tip of the pencil.
"00" will be shown on the display. (Picture 1)
MODE
4. Press
during pushing
will disappear and the air conditioner will turn OFF. The Remote Control B
is memorized. (Picture 2)
Note: 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
1
Cooling is abnormally low.
• The fi lters are blocked with dust.
• The temperature has been set
improperly.
• The windows or doors are opened.
• The air inlet or outlet of the outdoor
unit is blocked.
• The fan speed is too low.
• The operation mode is FAN or DRY.
. "B" will show on the display and "00"
2
11/20/57 BE 2:05 PM
11/20/57 BE 2:05 PM