Ambient Combustion Air - Johnson Controls TM9T Series Installation Manual

Two stage psc residential gas furnaces
Hide thumbs Also See for TM9T Series:
Table of Contents

Advertisement

1083286-UIM-L-1219
Gable
Vent
Ventilated
Attic
Optional
Top Above
Inlet (a)
Insulation
Soffit
Outlet
Vent
Air (a)
Gas
Water
Heater
Ventilated
Crawl Space
FIGURE 33: Ambient Combustion Air
Air Supply Openings and Ducts
1. An opening may be used in lieu of a duct to provide to provide the
outside air supply to an appliance unless otherwise permitted by the
authority having jurisdiction. The opening shall be located within 12"
(30.5 cm) horizontally from, the burner level of the appliance. Refer
to "AIR SOURCE FROM OUTDOORS AND VENT AND SUPPLY
AIR SAFETY CHECK" in these instructions for additional informa-
tion and safety check procedure.
2. The duct shall be either metal, or a material meeting the class 1
requirements of CAN4-S110 Standard for Air Ducts.
3. The duct shall be least the same cross-sectional area as the free
area of the air supply inlet opening to which it connects.
4. The duct shall terminate within 12" (30.5 cm) above, and within 24"
(61 cm) horizontally from, the burner level of the appliance having
the largest input.
5. A square or rectangular shaped duct shall only be used when the
required free area of the supply opening is 9 in
larger. When a square or rectangular duct is used, its small dimen-
sion shall not be less than 3" (7.6 cm).
6. An air inlet supply from outdoors shall be equipped with a means to
prevent the direct entry of rain and wind. Such means shall not
reduce the required free area of the air supply opening.
7. An air supply inlet opening from the outdoors shall be located not
less than 12" (30.5 cm) above the out40side grade level.
Combustion Air Source from Outdoors
1. Two permanent openings, one within 12" (30.5 cm) of the top and
one within 12" (30.5 cm) of bottom of the confined space, Two per-
manent openings, shall communicate directly or by means of ducts
with the outdoors, crawl spaces or attic spaces.
2. One permanent openings, commencing within 12" (30.5 cm) of the
top of the enclosure shall be permitted where the equipment has
clearances of at least 1" (2.54 cm) from the sides and back and 6"
(15.2 cm) from the front of the appliance. The opening shall com-
municate directly with the outdoors and shall have a minimum free
area of:
2
a. 1 in.
/ 3,000 BTU/hr (700mm2/kW) of the total input rating of all
equipment located in the enclosure.
b. Not less than the sum of all vent connectors in the confined
space.
28
Gas
Vent
Gable
Vent
Ventilated
Top Above
Insulation
Soffit
Vent
Gas
Water
Inlet
Heater
Air (b)
2
(58.06 cm
Gas
Vent
Attic
Outlet
Air (b)
Inlet
Inlet
Air (b)
Air (a)
3. The duct shall be least the same cross-sectional area as the free
area of the air supply inlet opening to which it connects.
4. The blocking effects of louvers, grilles and screens must be given
consideration in calculating free area. If the free area of a specific
louver or grille is not known, refer to Table 12.
Ventilated Combustion Air
The ventilated attic space or a crawl space from which the combustion
air is taken must comply with the requirements specified in "AIR
SOURCE FROM OUTDOORS" in this instruction or in Section 5.3, Air
for Combustion and Ventilation of the National Fuel Gas Code, ANSI
Z223.1 (latest edition). This type installation requires two properly sized
pipes. One brings combustion air from a properly ventilated attic space
or crawl space and a second pipe that extends from the furnace vent
connection (top right of unit) to the exterior of the building. Refer to
Table 7 for intake pipe sizing, allowable length and elbow usage. Follow
all notes, procedures and required materials in the "COMBUSTION
2
AIR/VENT PIPE SIZING" section in these instructions when installing
) or
the combustion air pipe from the unit and into a ventilated attic space or
crawl space. DO NOT terminate vent pipe in an Attic or Crawl Space.
Ventilated Combustion Air Termination
Refer to Figure 34 for required attic termination for the combustion air
intake pipe. For attic termination, use two 90 degree elbows with the
open end in a downward position. Be sure to maintain 12" (30.5 cm)
clearance above any insulation, flooring or other material.
A crawl space combustion air installation consists of a straight pipe
from the PVC coupling on the burner box that extends into the crawl
space and terminates with a 1/4" (6.4 mm) mesh screen and no elbows.
Gas
Vent
Outlet
Air (a)
Gas
Water
Inlet
Heater
Air (a)
Johnson Controls Ducted Systems

Advertisement

Table of Contents
loading

Table of Contents