Adjustment of the Fixed Cutter Knife

Requirement
When the needle bar is in it's lowest position the distance between the center of the needle (A) and the fi xed
cutter knife (B) should be 4 mm.
The thread cutter knife tip (E) should be aligned , when it swings out to its cutting position, with the left side of the edge
(H) of the fi xed knife.
Check
• Remove the needle plate and base.
• Set the needle bar to the lowest position.
• The distance between the center of the needle (A) and the fi xed cutter knife (B) should be 4 mm.
• Turn the hand wheel toward you while pushing up the link body (D) to engage the thread cutter knife (J) and bring it
under the fi xed knife (B).
• The thread cutter knife tip (E) should be aligned, when it swings out, with the left side of the edge (H) of the fi xed
knife.
Adjustment
• Remove the needle plate and base.
• Lower the needle bar to the lowest position.
• Loosen the setscrews (G).
• Adjust the position of the fi xed cutter knife (B) so that the distance between the center of the needle drop position (A)
and the fi xed cutter knife (B) is 4 mm.
• Tighten the setscrews (G).
• Turn the hand wheel toward you while pushing up the link body (D) to engage the thread cutter knife (E) and bring it
under the fi xed knife (B).
• The thread cutter knife tip (E) should be aligned, when it swings out, with the left side of the edge (H) of the fi xed knife.
If not Adjust Thread Cutter Knife.
• Attach the needle plate and base.
(A)
(E)
4 mm
(C)
(D)
104 72 63-26
(J)
(H)
(B)
4 mm
(B)
(G)