SET WEEKEND
PROGRAMS
SET WEEKDAY
SET DAY
PROGRAMS
AND TIME
ENERGY
AIR
USAGE
FILTER
RUN
DP722
1. FEATURES
Universal Compatibility
●
Controls Up To 2 Stages Of Heat And 2 Stages Of
●
Cooling + Auxiliary and Emergency Heat
Large Hybrid Display
●
Auxiliary and Emergency Heat Indicators
●
Electro-luminescent Display Backlight
●
Clean Cycle
®
(Patent No. 6,988,671)
●
Independently Programmable Fan
7 Day Programming
●
Default Program
●
4 Periods Per Day
●
Temporary Override
●
Temperature Hold
●
Optional Smart Recovery
●
Programmable Filter Timer With Change
●
Filter Indicator
Energy Usage Monitor
●
F/C Temperature Display
●
12/24 Hour Clock
●
Easy Programming with LUX Speed Dial
●
Advanced Copy Function For Fast Easy Programming
●
Nonvolatile Memory For All Programs And Settings
●
Daylight Saving Button
●
Multimode Keyboard Lockout With User
●
Programmable 3 Digit Code
Programmable High And Low Setting Limits
●
Silence-able Audible Button Response
●
Menu Driven Setup Done From The Front Panel
●
Temperature Offset (User Calibration)
●
Dual Power Capable (System/Battery)
●
Multi-Stage Adjustable Temperature Differential /
●
Cycle Rate
MODE
NEXT
Auto
Heat Off Cool
FAN
COPY
Auto On
DST
Setup
NEXT
EASY
PROGRAMMING
WITH
LUX SPEED DIAL
®
®
LARGE HYBRID DISPLAY
WITH ELECTRO-LUMINESCENT
DISPLAY BACKLIGHT
Programmable Length Minimum Run Time
●
Programmable Auto-Changeover Dead-Band
●
Programmable Fan Delays For Heat, Cool, In Both
●
On And Off
2. COMPATIBILITY
Your DP722 is compatible with most 24 volt gas, oil, or
electrical Heating and/or Cooling systems. It cannot be
used with 120 volt heating systems. Ask your dealer for
other PurePro thermostats to control those systems.
2.1. HEAT STAGES
The DP722 is capable of controlling systems with up to
two stages of heat in furnace mode. In heat pump mode,
the thermostat can be configured to control up to two
stages of compressor driven heat plus auxiliary and
emergency heat stages.
NOTE: AUX HEAT ACTIVATION IS PROVIDED AT
TERMINAL W1
2.2. COOLING/COMPRESSOR STAGES
The DP722 is capable of controlling systems with up to
two stages of cooling.
2.3. ELECTRICAL RATINGS
30V maximum (24VAC nominal)
●
1.5A maximum per terminal
●
2.0A terminal sum
●
3. INSTALLATION
3.1. TOOLS REQUIRED
#1 Phillips screwdriver (small)
●
Drill with 3/16-in. (4.8mm) bit
●
Wire stripper/cutter
●
3.2. LOCATION