MESSAGE
ERROR
WATER TEMP.
H5
ERROR
HEATER WASH
H6
ERROR
HEATER
WASH
H8
OVERHEATING
ERROR
IGBT
lb
ERROR
PUMP FILTER
PFE
ERROR
32
TROUBLESHOOTING GUIDE
CAUSE
The water temp. is over 45˚C in delicate & wool course.
(The thermistor wash is an inferior product or broke down.)
The heater wash dose not work.
(The water temp. doesn't rise over 2˚C during 15min.)
The heater worked without the water in the tub.
The PCB ASS'Y is an inferior product.
The drain pump filter is clogged.
The drain pump does not work during spin.
The large amount of detergent was used.
The drain hose is placed higher than 1m above the floor.
SOLUTION
Change the thermistor wash.
Change the heater wash.
Check the water level and the heater wash.
Change the PCB ASS'Y.
Clean the drain pump filter.
Change the drain pump.
Use the proper amount of detergent.
Place the drain hose 1m below the floor.