Abnormality
Diagnosis
or
LED 6 LED 5 LED 4 LED 3 LED 2 LED 1
display
protection
control
F96
Power
transistor
module
overheating
protection
F97
Compressor
overheating
protection
F98
Total running
current
protection
F99
Outdoor direct
current (DC)
peak detection
LED 1 illuminate is indicated that outdoor unit is operating normally. If the LED 1 is switched off or flashing, check the
power supply and self-diagnosis indication.
------ Illuminate
O ------ Flashing
Blank ------ OFF
O
O
O
O
O
O
O
O
O
O
O
O
Abnormality
Protection
judgement
operation
4 times
happen within
30 minutes
3 times
happen within
30 minutes
3 times
happen within
20 minutes
Continuous
happen for 7
times
32
Problem
Check location
Power transistor
 PCB faulty
module overheat
 Outdoor air
circuit (fan motor)
Compressor
 Insufficient
overheat
refrigerant
Total current
 Check
protection
refrigeration
system
 Power source or
compressor lock
Power transistor
 Power transistor
module current
module faulty or
protection
compressor lock