12 Technical Data; Overview: Technical Data; Service Space: Outdoor Unit - Daikin RZASG100M7V1B RZASG125M7V1B RZASG140M7V1B Installer's Reference Manual

Hide thumbs Also See for RZASG100M7V1B RZASG125M7V1B RZASG140M7V1B:
Table of Contents

Advertisement

12
Technical data
A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is
available on the Daikin extranet (authentication required).
12.1

Overview: Technical data

This chapter contains information about:
• Service space
• Piping diagram
• Wiring diagram
12.2

Service space: Outdoor unit

Suction side
In the illustrations below, the service space at the suction side is based on 35°C DB and cooling operation. Foresee
more space in the following cases:
▪ When the suction side temperature regularly exceeds this temperature.
▪ When the heat load of the outdoor units is expected to regularly exceed the maximum operating capacity.
Discharge side
Take refrigerant piping work into account when positioning the units. If your layout does not match with any of the
layouts below, contact your dealer.
Single unit (
) | Single row of units (
e
B
E
e
D
e
C
H
b
c
U
d
D
H
D
e
B
E
e
D
e
C
H
≥100
c
U
b
d
D
H
D
A,B,C,D
Obstacles (walls/baffle plates)
E
Obstacle (roof)
a,b,c,d,e
Minimum service space between the unit and obstacles A, B, C, D and E
e
Maximum distance between the unit and the edge of obstacle E, in the direction of obstacle B
B
e
Maximum distance between the unit and the edge of obstacle E, in the direction of obstacle D
D
H
Height of the unit
U
H
,H
Height of obstacles B and D
B
D
1
Seal the bottom of the installation frame to prevent discharged air from flowing back to the suction side through the bottom of the unit.
2
Maximum two units can be installed.
Not allowed
RZASG71~140M_V1+Y1
Sky Air Advance-series
4P486047-1 – 2017.04
)
A~E
B
A, B, C
B, E
A, B, C, E
D
D, E
B, D
B
B, D, E
H
H
B
a
H
A
A, B, C
A, B, C, E
D
D, E
B, D
H
H
B
½H
H
B
B, D, E
H
≥100
H
a
A
H
H
H
B
D
U
a
≥100
≥250 ≥100 ≥100
≥100
≥250 ≥150 ≥150
≥100
<H
H
≤½H
≥250
B
D
B
U
½H
<H
≤H
≥250
U
B
U
H
>H
B
U
>H
H
≤½H
≥100
B
D
D
U
½H
<H
≤H
≥200
U
D
U
H
>H
D
U
≥250 ≥300 ≥1000
≥250 ≥300 ≥1000
>H
≥300
D
U
≤½H
≥250
D
U
<H
≤H
≥300
U
D
U
<H
H
≤½H
≥300
B
D
B
U
½H
<H
≤H
≥300
U
B
U
H
>H
B
U
>H
H
≤½H
≥250
B
D
D
U
½H
<H
≤H
≥300
U
D
U
H
>H
D
U

12 Technical data

(mm)
b
c
d
e
e
B
≥1000
≥1000
≥500
≥500 ≥1000 ≤500
≥500
≥750 ≥1000 ≤500
≥1000 ≥1000 ≤500
≥1000 ≥1000
≥1000 ≥1000
≥1000
≥1000
≥1000 ≥1000 ≤500
≥1000
≥1500
≥1500
≥1000 ≥1000 ≤500
≥1250 ≥1000 ≤500
≥1000 ≥1000
≥1000 ≥1000
Installer reference guide
e
D
≤500
≤500
1
≤500
≤500
≤500
1+2
≤500
≤500
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents