9. Turn on water supply and allow
at least four gallons of water to
flush through the filter. Turn off
water supply.
10. Cut the tubing to the proper
length and connect a stem elbow
fitting to the cut end of tubing.
Thread the ¾" female garden hose
onto the brewer inlet valve located
at the lower rear of the brewer.
Push the stem elbow fitting into it
until secured firmly. Then, turn on
water supply.
NOTE: Water and waste piping and connections shall
comply with the International Plumbing Code 2003,
International Code Council (ICC) or the Uniform
Plumbing Code 2003, International Association of
Plumbing and Mechanical Officials (IAPMO).
Screws (4x)
Filter Mounting
Bracket
IN PORT
Shut-off Valve
LLDPE Tubing
OUT PORT
Threaded Straight
Adapter
Stem Elbow Fitting
3/4" Female Garden
Hose Connector