INSTALLATION

DRED Connection (optional)

This appliance is supplied with an DRED interface, the interface provides two connection methods of either a four
wire terminal connection or an RJ45 socket.
Must be installed, maintained and removed by authorised persons in accordance with AS/NZS
3000 and to all other relevant local regulations and municipal building codes including OH&S
WARNING
requirements.
Ensure electric wiring is installed properly. Improper installation may cause malfunction, fire, or
electric shock.
1.
Remove the wiring cover.
2.
Connect the power feed to the terminal block as shown on the drawing below.
3.
Connect the communication cable to DRED interface using either the four wire terminal connections or RJ45
socket provided.
Wiring
cover
4.
Re-install the wiring cover.

CONDENSATE DRAIN INSTALLATION

A condensate drainage point is provided in the base of the outdoor unit.
For the purposes of drainage a barbed elbow is also supplied.
Insert the barbed elbow into the drainage point of the outdoor unit as shown.
A drainage hose (installer to supply) will need to be fitted.
Drainage of the condensate must conform with all local regulations
and municipal building codes including local OH&S requirements.
IMPORTANT
Rinnai
N
S
L
RJ45
DCSR
All Other Outdoor Models
S
N
LO
L
RJ45
DCSR
12
HONRJ80B ONLY
Split AC IM