Welding Process Change - Lincoln Electric PF22 Operator's Manual

Table of Contents

Advertisement

Table 1
LED Light
Only machines which using ArcLink
Condition
protocol for communication
Steady Green
System OK. Power source is
operational, and is communicating
normally with all healthy peripheral
equipment.
Blinking Green Occurs during power up or a system
reset, and indicates the power source
is mapping (identifying)
each component in the system.
Normal for first 1-10 seconds after
power is turned on, or if the system
configuration is changed during
operation.
Alternating Green
If the status lights are flashing any
and Red
combination of red and green, errors
are present in the power source.
Individual code digits are flashed in
red with a long pause between digits.
If more than one code is present, the
codes will be separated by green
light. Read the error code before the
machine is turned off.
If occurs, to clear the error try to turn
Off the machine, wait for a few
seconds, then turn ON again. If the
error remains, a maintenance is
required. Please contact the nearest
authorized technical service center or
Lincoln Electric and report the error
code read.
Steady Red
Indicate no communication between
the power source and device which
has been connected to this power
source.
21. Thermal Overload Indicator: It indicates that the
machine is overloaded or that the cooling is not
sufficient.
22. LED Indicator: Informs that the value on the right
display is in volts unit.
23. LED Indicator: Informs that the value on the right
display is Trim. Trim is adjustable from 0.50 to 1.50.
1.00 is the nominal setting.
24. Right Control: Adjusts values on the right display.
25. LED Indicator: Informs that the Crater Procedure is
activated.
26. LED Indicator: Informs that the Wave Control
Procedure is activated.
27. Right Button: Enables scrolling, changing and setting
welding parameters:
Crater
Wave Controls
28. LED Indicator: Indicates that the Settings and
Configuration Menu is activated.
English
Meaning
®
29. Left Button: Enables:
Checking the program number assigned to
active memory. To check the program number,
press the Left Button ones.
Changing the Welding Process.
30. Welding Programs Indicators (unchangeable): LED
indicates the unchangeable program for non-
synergic process is active. See the table 2.
31. Welding Programs Indicators (changeable): In the
user memory can be stored four user programs. LED
indicates that the changeable program is active. See
the table 3.
32. Left Control: Adjusts values on the left display.
33. LED Indicator: Informs that the value on the left
display is in ampere units.
34. LED Indicator: Informs that the wire feed speed is on
the left display.

Welding Process Change

It is possible to quick recall of one of the eight welding
programs. Four programs are fixed and cannot be
changed - Table 2. Four programs can be changed and
assigned to one of four user memory - Table 3.
Table 2: Unchangeable Welding Programs [30]
Symbol
Process
GMAW
(non-synergic)
FCAW-GS
Note: The list of available programs depends on the
power source. If the power source does not operate the
one of four unchangeable programs, the LED [30]
indicating this program does not light up.
Table 1. Changeable Welding Programs [31]
Symbol
Process
Synergic GMAW
Ø1.0, Steel, MIX
Synergic GMAW
Ø1.2, Steel, MIX
Synergic GMAW
Ø1.2, AlMg, Ar
Synergic GMAW
Ø1.0, Stainless,
Note: The list of available programs depends on the
power source. If the power source does not operate the
program form table 3, the first available welding program
is loaded in lieu of an unsupported welding program.
To change the welding process:
Press the Left Button [29]. "Pr" is shown on the left
display and the program number on the Right [19].
Again, press the Left Button [30] the weld program
indicator [30 or 31] will jump to the next in the
sequence shown in Figure 6.
7
Program Number
5
7(155)
SMAW
1
GTAW
3
Program Number
11
21
75
31
MIX
English

Advertisement

Table of Contents
loading

This manual is also suitable for:

K14110-1