Horizontal Installation; Electrical System; Installation Of The Thermostat - Bryant OVM098 Installation Instructions Manual

Multipoise oil furnace
Hide thumbs Also See for OVM098:
Table of Contents

Advertisement

Available languages

Available languages

AMP098 in downflow position requires the protection plate.
Figure 3 – Downflow Installation

2.2.3 Horizontal Installation

When the furnace is installed in the horizontal position, either
suspended or on a combustible floor with a choice of right or left
discharge, the clearances from combustible material must be adhered
to. If the unit is installed on a combustible floor, the horizontal floor base
HFB-101 or KLASB0701DET can be used to ensure these clearances.
Refer to the instructions supplied with the base.
In cases where the return air enters through the floor, the floor return
base FRB-101 or KLARB0101DET can be installed as per the supplied
instructions.
The burner must always be installed in the same manner, regardless of
the discharge position of the furnace. Refer to Figure 4 for additional
details.
Figure 4 – Horizontal Installation

2.3 ELECTRICAL SYSTEM

CAUTION
The exterior of the unit must have an uninterrupted ground to
minimize the risk of bodily harm, if ever an electrical problem
develops. A green ground screw is supplied with the control box
for that purpose.
The appliance must be installed in accordance with the current
ANSI/NFPA 70 National Electrical Code, CSA C22.1 Canadian
Electrical Code Part 1 and/or local codes.
The control system depends on the correct polarity of the power supply.
Connect "HOT" wire (H) and "NEUTRAL" wire (N) as shown in figures
10 and 11.
A separate line voltage supply should be used, with fused disconnect
switch or circuit breaker, between the main power panel and the unit.
Only copper wire may be used for the 115V circuit on this unit. If
wires need to be changed, the replacements must have the same
temperature resistance as the originals.
2.4 INSTALLATION OF THE
THERMOSTAT
A thermostat must be installed to control the temperature of the area to
be heated. Follow the instructions supplied with the thermostat. Also
refer to the wiring diagrams provided with the heating/air conditioning
unit. The connections must be made as indicated on the following
diagrams and the wiring diagrams, Figure 10 and Figure 11.
Figure 5 – Thermostat wiring, heating and air
conditioning with 4-speed motor
Figure 6 – Thermostat wiring, heating and air
conditioning with ECM variable speed motor
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Obm098098 series

Table of Contents