9. Pump-Out Pump Motor Direction (S5 dip switch 1)

Do not adjust. This must be left in the factory default position or the icemaker will
not operate correctly.
The pump-out pump motor direction setting determines pump motor rotation during
pump-out.
On models with a drain valve pump motor rotation doesn't change at pump-out.
Pump motor rotates in forward direction and drain valve is energized for pump-out.
On models with a check valve, pump motor rotation reverses at pump-out.
Pump motor rotates in reverse direction and opens check valve for pump-out.
S5 Dip Switch Setting
No. 1
OFF
ON

10. Refill Counter (S5 dip switch 2 and 3)

Do not adjust. These must be left in the factory default position or the icemaker will
not operate correctly.

11. Minimum Harvest Time (S5 dip switch 4)

Factory set for proper operation. Do not adjust. Adjustment outside the factory
default setting may result in damage to the appliance.
NOTICE
Pump-Out Components
Pump Motor Forward Rotation and Drain Valve
Pump Motor Reverse Rotation and Check Valve
NOTICE
S5 Dip Switch Setting
No. 2
No. 3
OFF
OFF
OFF
ON
ON
OFF
ON
ON
NOTICE
S5 Dip Switch Setting
No. 4
OFF
ON
41
Refill
Counter
0
1 refill
9 refills
10 refills
Minimum
Harvest Timer
120 sec.
70 sec.