Electrical Requirements

Dangerous Voltage
A 220–240V, 50 Hz., fused electrical supply is required. A
time-delay 10–16A fuse or circuit breaker is recommended.
This washer is equipped with a power supply cord having
a 3 prong earthed plug.
To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
earthed in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly earthed
outlet installed by a qualified electrician.
If codes permit and a separate earth wire is used, it is
recommended that a qualified electrician determine that
the earth path is adequate.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent, or a qualified person
to avoid a hazard.
Do not earth to a gas pipe.
Check with a qualified electrician if you are not sure
the washer is properly earthed.
Do not have a fuse in the neutral or earth circuit.
EARTHING INSTRUCTIONS
This washer must be earthed. In the event of a malfunction
or breakdown, earthing will reduce the risk of electric
shock by providing a path of least resistance for electric
current. This washer is equipped with a cord having an
equipment-earthing conductor and an earthing plug. The
plug must be plugged into an appropriate outlet that is
properly installed and earthed in accordance with all local
codes and ordinances.
WARNING:
Improper connection of the equipment-
earthing conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in
doubt as to whether the appliance is properly earthed.
Do not modify the plug provided with the appliance – if it will
not fit the outlet, have a proper outlet installed by a qualified
electrician.
NOTE: Electrical safety standards: The manufacturer has
chosen compliance with IEC/EN.60335 standards as the most
appropriate for this product.
Sound Pressure Level, Lpa: 58 dbA (uncertainty,
Kpa: +/-3.6 dbA)
7