Page 1
I1203S Wood Insert Owners & Installation Manual www.regency-fire.com Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 919-060d 01.30.18...
Page 2
The following statements are required by the Environmental Protection Agency: “This manual describes the installation and operation of the Regency I2403 wood heater. This heater meets the 2015 U.S. Environmental Protection Agency’s crib wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 12,000 BTU/hr. to 36,800 BTU/hr.”...
table of contents SAFETY LABEL OPERATING INSTRUCTIONS Safety Label..............4 First Fire ..............18 Fan Operation..............19 Ash Disposal..............19 UNIT DIMENSIONS Some Safety Guidelines ..........19 MAINTENANCE With standard flue adaptor ..........5 With offset flue adaptor ..........6 Creosote ..............19 Maintenance Of Gold-plated Doors ......20 INSTALLATION Door Gasket ..............20 Door Latch Adjustment ..........20...
This is a copy of the label that accompanies each I1203S Wood Insert. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
1) Read all instructions before installing and be supplied with appropriate supporting means. using your fireplace insert. Install and use Regency Inserts are designed to use either a only in accordance with manufacturer’s 10) Installer must mechanically attach the supplied installation and operating instructions.
Hearth Hearth Side Unit (to Side) (to Top of Unit) (to Side of Unit) Extension* Thickness Extension* I1203S 15" (381mm) 20" (508mm) 14" (356mm) 7-3/8"(187mm) 16" (406mm 1.5" (38mm) 8" (203mm) 18-3/4"(476mm) Side and Top facing is a maximum of 1.5" thick.
installation INSTALLING 3) Install the unit by first setting the rear of 7) Ensure that the unit is still level. the unit into the fireplace. See diagram YOUR INSERT 3. Ensure that the unit is centered in the 8) To complete the installation and to ensure a existing fireplace and lined up with the flue secure fit and connection of the flue adaptor adaptor.
“breathe” better by allowing a greater draft to be created. The greater draft can Regency highly recommends the use of a full decrease problems such as, difficult start-ups, liner as the safest installation and provides the smoking out the door, and dirty glass.
installation STAINLESS STEEL SMOKE DEFLECTOR ADJUSTMENT / REPLACEMENT The stainless smoke deflector is located in the upper front area of the firebox. The deflector is held in place with 2 bolts Prior to the first fire, ensure deflector is seated properly and secured with 2 hand tightened bolts. Ensure defector is seated so bolts are situated at the top of the keyhole before tightening.
I1200 installation FACEPLATE, TRIM, FAN & OPTIONAL FACEPLATE, TRIM & OPTIONAL BOTTOM FACEPLATE & FAN SUPPORT INSTALLATION BOTTOM FACEPLATE & FAN SUPPORT INSTALLATION Regular Faceplate Dimensions (shown with bottom faceplate/fan support attached): Oversize Faceplate Dimensions (shown with bottom faceplate/fan support attached): | 1203S 09/02/16 918-676d...
Page 13
I1200 installation Regular/Oversize Faceplate Installation: Optional Regular/Oversize Bottom Faceplate Installation: 1) Thread the black 1/4" x 3/4" long hex bolts into the faceplate mount- ing bracket as shown in Diagram 1, leaving them approximately 1/4" 4) Position the assembled faceplate side and top to the insert. Ensure out.
Page 14
I1200 installation Regular/Oversize Faceplate Trim Installation: 11) Mount the completed faceplate / trim assembly to the insert. Ensure to align the side faceplate slots with the hex bolts in the mounting (Black Trim included with Regular/Oversize Faceplate brackets and tighten to secure in place. or Bottom Faceplate) Fan Installation: 8) Assemble the left and right side trim to the top trim using the trim clips...
Page 15
I1200 installation 14) Cut the bottom edge of the fan support and bottom faceplate (using 18) Secure the bottom faceplate to the 3-sided faceplate using the 4 a metal cutting blade) to the length measured in step 13. supplied bolts/washers. 15) Remove the fan assembly from the ash lip of the insert and position 19) Discard both side trims that were included with the regular/oversize the fan support to the bottom of the fan assembly.
installation Installer: Please record unit serial number here before installing blower. Serial No.______________________________ FAN / BLOWER with any hot stove surfaces. WARNING: Electrical Grounding Instructions Do not turn fan ON until your insert has Your fan should only be installed once the unit This appliance is equipped with a reached operating temperature or at least is in place in order to prevent any damage to...
installation BRICK FLUE BAFFLE & 4) Important: push both baffle bricks so they are tight against the side walls and SECONDARY AIR TUBE FIREBRICK ASSEMBLY to the back. INSTALLATION Firebrick is included to extend the life of your insert and radiate heat more evenly. Check to The flue baffle system located in the upper area see that all firebricks are in their correct posi- of the firebox is removable to make cleaning...
installation SCREEN DOOR 8) Do not place anything on the insert top this section can cause serious permanent during the curing process. This may result damage to the unit and void your warranty. in damage to your paint finish. Hook screen to the inside on the right side FIRST FIRE of the firebox door opening.
During constant use, ashes should be removed 9) Your Regency Insert can be very hot. You has been done. In the event that removal is re- every few days. Please take care to prevent the...
REPLACEMENT If the door gasket requires replacement, 7/8" diameter material must be used. A proper high Your Regency Insert is supplied with 5 mm. temperature gasket adhesive is required. A Neoceram ceramic glass that will withstand gasket repair kit, Part # 846-570 is available the highest heat that your unit will produce.
parts list FACEPLATES Part # Description 171-920 Faceplate & Trim Set - Regular - Black 171-924 Trim Set - Regular Brass 60) * Faceplate Right Side Regular / Oversize 171-570 Trim Set - Regular Black 61) * Faceplate Left Side Regular / Oversize 62) * Faceplate Top Regular / Oversize 171-922...
parts list FIREBRICK Part # Description 170-960 Complete Brick Set 70) * Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 76) * Brick Partial: 1-1/4" x 2" x 9" 81) * Brick Partial: 1-1/4" x 1-1/4" x 9" 84) * Brick Partial: 1-1/4"...
Page 24
At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. | 1203S Revision Date: December 2016 Regency Wood Products Warranty...
Page 25
Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: December 2016 Regency Wood Products Warranty 1203S |...
Page 26
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx...
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.