To disable sunlight sensor check mode
After check mode is ended (5 minutes counter elapsed), press AUTO OFF/ON button at indoor unit.
o
If the sunlight sensor detected sunlight intensity is at abnormal range, the check mode will be ended.
o
Please check for error code.
14.11.1.6
Sunlight Sensor Abnormality
Abnormality detection:
When ECONAVI is ON, if the sunlight intensity value below minimum level continuously for 24 hours, the
o
sunlight sensor disconnection error counter will increase by 1 time. If the ECONAVI is OFF, the 24 hours
timer will be reset, but the sunlight sensor disconnection error counter will not be reset.
Error Code judgment
When sunlight sensor disconnection error counter reached 15 times, H70 occurred.
o
No TIMER indicator or ECONAVI indicator blinks.
o
When error code happened, the unit is able to operate without sunlight sensor.
72