Panasonic CS-HZ25TKE Service Manual page 34

Hide thumbs Also See for CS-HZ25TKE:
Table of Contents

Advertisement

6
Secure the connection cable onto the control board with the holder.
WARNING
This equipment must be properly earthed.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor's respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
12.2.4.1
Wire Stripping and Connecting Requirement
WARNING
RISK OF FIRE
JOINING OF WIRES MAY
CAUSE OVERHEATING
AND FIRE.
Terminal
Board
Recommended
length (mm)
a b c d
Recommended
length (mm)
50 40 35 60
Wire stripping
No loose strand
when inserted
Conductor
fully inserted
ACCEPT
In case of indoor power supply
OR
O
R
O
R
d
a
b
c
4
Indoor & outdoor
connection cable
Outdoor unit
Indoor/outdoor
connection
terminal board
5 mm or more
(gap between wires)
Conductor over
Conductor not
inserted
fully inserted
PROHIBITED
PROHIBITED
Use complete wire without
joining.
Use approved socket and
plug with earth pin.
Wire connection in this
area must follow to
national wiring rules.
Do not joint wires
34
Control
Board
Earth wire
longer than
others
AC wires
for safety
reason
Holder
Tape
Connection
cable
In case of outdoor power supply
OR
OR
OR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-hz25tkeCshz-35tkeCu-hz35tkeCs-hz25tke-5Cu-hz25tke-5

Table of Contents