3

Technical data

3 Technical data
Weight
Casing material
Gaskets material
Protection class
Air supply and vent connections
Air line connections
Electrical connections
Field bus connections
Vibrations
Storage temperature
Air supply
Single Acting Valves
Double Acting Valves (1 normally open and 1 normally closed), Mixproof and Twin-Stop
valves (2 normally closed)
Mixproof valves with air supply for opening, top and bottom lift (3 normally closed)
Electrical power supply
Air pressure supply
Ambient temperature for solenoid valve type B
Ambient temperature for solenoid valve type S
Electrical power supply
Ambient temperature
No. / type of inputs
No. / type of outputs
Ambient temperature
MAX absorbed current
MAX total current (IN + OUT)
AS-interface profile
As-interface specification
AS-interface IC
Extended addressing mode
Solenoid valves type "B"
Solenoid valves type "S"
EN-IST-GIOT360-1021
CONTROL UNIT TECHNICAL DATA
from 0.55 Kg to 0.65 Kg depending on the configuration
PA66 + PA6-GF30 (glass fibre reinforced nylon)
NBR / EPDM
IP67
1/8" BSP
6 mm / (1/4" ON REQUEST)
7-pole connector, M12 5 pole connector, M12 8 pole connector,
M12 12 pole connector
Threaded fitting for cable gland PG11 or M20x1.5
Actuator Sensor interface (AS-i).
1mm amplitude f=10..55Hz
from -10°C to +25°C
Class 2,4,3 according to ISO 8573-1
SOLENOID VALVE APPLICATION CRITERIA
SOLENOID VALVE TECHNICAL DATA
INDUCTIVE SENSOR TECHNICAL DATA
24 Vdc
-25..+80°C
AS-I CARD TECHNICAL DATA
24 Vdc ±10%
max. 7bar
min. 6bar
0..+55°C
-10..+50°C
4 / PNP
3 / PNP
-25..+70°C
220 mA
150 mA
S-7.A.7.F
V 3.0
ASI4U
ü
ü
ü
1 Solenoid valve
2 Solenoid valves
3 Solenoid valves
9