Robertshaw RS8210 Operation Manual page 11

Hide thumbs Also See for RS8210:

Advertisement

Filter Change
Feature
Reminder
Factory default
OFF
settings
This setting will
flash FILT in the
display after the
elapsed run time
Feature
to remind the
Description
user to change
the filter.
The OFF setting
will disable
this feature.
LCD will show
Room
Temperature
Compressor
Calibration
0°F
OFF
This setting
allows the
installer to
The installer
change the
can select the
calibration
minimum run
of the room
time for the
temperature
compressor to
display so that,
help protect the
for example,
compressor from
the thermostat
short-cycling.
would read 72°F
instead of 70°F.
Next Step
Next Step
Prev Step
Prev Step
Done
Done
INSTALLER SETUP MENU
Minimum
Compressor
Short Cycle
On-Time
Delay
On
The compressor
short cycle delay
setting
will not allow the
compressor to
be turned on for
5 minutes after
it was last
turned off in
order to protect
the compressor.
Next Step
Prev Step
Done
Cooling
Differential
0.5°F
0.4°F
The cooling
differential is
factory preset at
0.5°. This means
factory preset at
that whenever
0.4°. This means
the room
that whenever the
temperature
room temperature
heats by 0.5°
full degree from
0.4° from the
the temperature
setting, the
cooling system
heating system
will turn on.
will turn on. If the
If the cooling
heating system
system turns
on too often,
often, increase
increase the
the temperature
temperature
differential.
Next Step
Next Step
Prev Step
Prev Step
Done
Done
Heating
Differential
The heating
differential is
cools by
temperature
setting, the
turns on too
differential.
Next Step
Prev Step
Done
9