Approximately 5 ft (1.5m) from floor.
S
Close to or in a frequently used room, preferably on an inside partition-
S
ing wall.
On a section of wall without pipes or duct work.
S
AC/HP Control should NOT be mounted:
Close to a window, on an outside wall, or next to a door leading to the
S
outside.
Exposed to direct light or heat from a lamp, sun, fireplace, or other tem-
S
perature- radiating objects which could cause a false reading.
Close to or in direct airflow from supply registers and return- air regis-
S
ters.
In areas with poor air circulation, such as behind a door or in an alcove.
S
Installer should determine whether control will be installed as single- piece or
two- piece. In single- piece configuration, as many as 14 wires may need to run to
wall mounting location for connection to the control. In two- piece configuration,
the Display Module and Equipment Control Module are connected by two wires.
Install AC/HP Control
!
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing AC/HP Control, turn off all power to equipment.
There may be more than 1 power disconnect.
WARNING
9