Swing Motors

7. Swing Motors
Warning
Step
1. Remove the air outlet
ASSY.
Remove the 2 screws
1
of the air outlet ASSY.
Unfasten the lower 4
2
hooks and upper 3
hooks.
Remove the air outlet
3
ASSY.
2. Remove the vertical blade
ASSY.
1
Release the 2 shafts of
the vertical blade
ASSY.
Unfasten the 2 hooks.
2
22
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Hook
Hook
Hook
Shaft
Air outlet ASSY
(R19888)
(R19889)
(R19890)
Hook
(R19891)
Si041411E
Points
Removal Procedure