Horizontal Swing Motors - Daikin FTXM09VVJU Service Manual

Hide thumbs Also See for FTXM09VVJU:
Table of Contents

Advertisement

Horizontal Swing Motors

5. Horizontal Swing Motors
Warning
 Be sure to wait for 10 minutes or more after turning off all power supplies before
Step
1. Remove the horizontal
blade (1).
1
Release the center
shaft(s) while bending
the horizontal blade (1)
slightly.
2
Release the left shaft.
3
Release the right key
pattern shaft and
remove the horizontal
blade (1).
2. Remove the swing motor
for the horizontal blade
(2).
1
Remove the screw.
2
Pull out the swing motor
while turning it a little to
the left.
3
Disconnect the
connector of the swing
motor.
14
disassembling work.
Procedure
Horizontal blade (1)
Left
Shaft
Connector
Swing motor for horizontal blade (2)
Center shaft
(R26169)
(R26170)
(R26172)
Points
 Installation procedure
(1) Since the key pattern shaft is
provided, rotate the
horizontal blade and fit it to
the right shaft first.
(2) Fit the horizontal blade to the
center and left shafts.
 18/24 class have 2 center
shafts.
Right
Key pattern shaft
Removal Procedure
Si042153E
(R26171)