Singer 9876 Service Manual page 41

Household sewing machine
Table of Contents

Advertisement

Service Manual
Removal:
1. Set machine to number "5" stitch length (maximum).
2. Turn hand whell toward the front of the machine to locate the feed dog at its
furthest rear position.
3. Remove the free arm extension table, bed bottom cover and extension table bottom
cover.
4. Loosen screws (F) to swing bracket (D) clear of eccentric stud (G).
5. Slightly depress feed bar assembly (H) until the fork on the feed lifting lever (C)
clears the pin ( I ) on the feed bar.
6. Draw the feed lifting lever assembly (C) down and to the left out of the machine.
Replacement:
1. Replacement is the same as removal in reverse order.
2. Position the eccentric stud (D) making sure spacer (A) is positioned with the hole
offset against the feed lifting lever bushing.
3. Adjust feed dog height.
4. Tighten screws (F). Be sure spring (B) is properly located in the hole in the casting
and over the setour in the feed lifting lever (C).
Rev. no.
MAR/05
Feed lifting lever assembly
(for machines without drop feed)
40
P/N 358426002