B.4 Programming User Codes
WP Panel system allows you to authorize up to 8 people (WP Panel) / 48 people (WP Panel) to arm and disarm
the system by providing each with a unique 4 digit personal security code, and assigning them with different
security levels and functionalities. Moreover, you can obtain up to 8 (WP Panel) multi-function portable keyfob
transmitters that will allow you and the other users to easily arm, disarm and control the system without
accessing the panel, including from outside the premises (see section B.7 Add / Delete Keyfob Transmitters).
The Duress Code enables you to disarm the system using a special code that sends a silent alarm to the
monitoring station.
There are two types of users: Master User and User. The table below summarizes the different operations that
can be performed by different users:
User type
Function
Arm/disarm
Master User
Zone bypass
Authorize other user codes
Set user codes
Report to private
Enroll/delete proximity tag
Enroll/delete keyfob
Automatic arming
Enable squawk
Set date and time format
Read event log
Programming the duress code
Programming the scheduler
Enabling/disabling voice option
Adjusting volume of system
beeps, chime signal and voice
prompts,
Arm/disarm
User
Zone bypass options
The user codes are assigned as follows:
User Code 1 is assigned to the Master User of the system (i.e. the owner). It is the only user code that allows
access to the User Settings menu. The default setting of the Master User code is 1111. This code cannot be
erased and must be replaced with a secret code as soon as possible.
User Codes 2-4 (WP Panel) / User Codes 2-22 and 33-48 (WP Panel) are assigned to family members, co-
workers etc. They enable arming and disarming of the system or of selected partitions as defined by the Master
User. They can access the "User Settings" menu only for "zone bypassing" provided this option is enabled in
the Installer menu.
User Codes 5-8 (WP Panel) / User Codes 23-32 (WP Panel) are the same as user codes 2-4 / 2-22 but can
be assigned to "Latchkey" (child monitor) users. For a detailed explanation of the Latchkey application see
Chapter 2 (Arming in the Latchkey Mode) and Appendix C.
Partition Option (For information about Partition option - see Appendix B)
Your alarm system can divide zones into up to 3 parts (groups) via the installer menu. These parts are
designated as partitions P1, P2 & P3. Each partition can be armed and disarmed separately providing
protection to selected parts of the premises.
Each user out of the 8 (WP Panel) / 48 (WP Panel) system users can be authorized by the Master User to arm
and disarm any combination of partitions including all 3 partitions.
 Here you can program (or edit) the 8 (WP Panel) /48 (WP Panel) User Codes and thereby define which of
these will be authorized to arm and disarm.
1. The default setting 1111 of the Master User Code is the same for all WP Panel systems and is known
to many other people. Therefore, we highly recommend that you immediately replace it with a unique
secret code. Never set any user code the same as any installer code.
2. Code "0000" is not valid! Do not use it.
3. The duress code (2580 by default), which is set in the installer menu, cannot be selected as a normal
user code. Any attempt to program it will be rejected by the system.
4. Carefully read the section titled "Additional Information" according to the indicated references
see table at end of this section.