MOUNTING THE LIGHT FIXTURE

1. Make sure wire connectors and wires are inside the
junction box.
2. Slide the fixture assembly onto the mounting screws.
Tighten decorative nuts removed in step 1 of Light
Fixture Installation section securely against fixture base.
Decorative Nut
3. Install one medium base light bulb (100 Watt maximum,
tungsten incandescent).
4. Caulk around fixture base with silicone weather sealant.
Caulking Around Fixture Base
The TEST mode overrides the photocell (daylight shutoff
feature) and allows the light fixture to be tested day or night
when the ON-TIME switch is in the TEST position. The
light will stay on for 5 seconds after all motion has stopped.
Mounting Screw
1. Set the ON-TIME control to TEST.
2. Set sensitivity control (SENS) to MIN position.
3. Turn on the circuit breaker or fuse and the light switch.
4. Allow the sensor to completely warm up (40 seconds)
5. Perform a walk test. Walk in an arc across the front of
Junction
Box
(1 .8 m)
6

TESTING AND ADJUSTMENTS

Initial Setup
ON-TIME
TEST 1 5 10
MIN
Sensor Controls
before beginning the setup process.
the sensor.
6 ft .
30 ft . (9 .1 m)
Maximum Range
+
SENS
Maximum
Coverage Angle
(Top View)
209177-03