Olden Cap Replacement - HTC SkyWriter Service Manual

Table of Contents

Advertisement

Doc. Title
Appendix 1
Notification once performing Golden cap replacement
If you perform M/B replacement, must take care for following notices:
1. If you use hot gun to replace any component or use solder iron to replace component that next
to G/C .Please use solder iron to remove golden capacitor before repairing.
gun to remove golden capacitor to prevent damage.
2. If repaired M/B was removed G/C before repairing. Please use solder iron to change new G/C to
M/B after repaired. The condition of solder iron as bellow:
(1) The temperature of solder iron must be under 350 degree C ( for lead-in model ) , 380
degree C (for lead-free model).
(2) The heating time of solder iron must be under 5 seconds.
(3) Solder iron can not contact with the body of G/C.
(4) Prohibit recycling use golden capacitor to product.
HTC confidential
© 2008 HTC CORPORATION. ALL RIGHTS RESERVED.····························································
TOTAL 83
宏達國際電子股份有限公司
HTC Corporation
SkyWriter Service Manual
Gold Cap
PAGE NO. 81
Doc. No.
DOC-00045404
Issued Date
2008/08/18
Revised Date
2008/08/15
Page
81 of 83
Prohibit using hot
REV.
A01

Advertisement

Table of Contents
loading

Table of Contents