Parameter Settings For A Motor With Encoder - Mitsubishi Electric 800 Series Instruction Manual

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

2.10
Parameter settings for a motor with
encoder
Parameter for the encoder (Pr.359, Pr.369, Pr.851, Pr.852)
• Set the encoder specifications.
Pr.
Name
359
852
Encoder rotation
C141
C241
direction
369
851
Number of
C140
C240
encoder pulses
The parameters above can be set when a vector control compatible option is installed.
• The following table shows parameters to be set according to a vector control compatible option to be used.
Item
Encoder/Resolver rotation direction
Number of detector pulses
Initial
Setting
value
range
Set when using a motor for which forward rotation
0
(encoder) is clockwise (CW) viewed from the shaft
100
1
Set when using a motor for which forward rotation
1
(encoder) is counterclockwise (CCW) viewed from
the shaft
101
Set the number of encoder pulses output.
1024
0 to 4096
Set the number of pulses before it is multiplied by 4.
FR-A8AP/FR-A8AL/
FR-A8APR
FR-A8APA
parameter
parameter
Pr.359
Pr.369
― (fixed 1024 pulses)

Parameter settings for a motor with encoder

Description
CW
CCW
FR-A8APS
parameter
― (Obtained via
communication from
the encoder)
INSTALLATION AND WIRING
Set for the operation at
120 Hz or less.
Set for the operation at
a frequency higher
than 120 Hz.
Set for the operation at
120 Hz or less.
Set for the operation at
a frequency higher
than 120 Hz.
FR-A8TP
parameter
Pr.852
Pr.851
2
59

Advertisement

Table of Contents
loading

Table of Contents