OUTDOOR UNIT REMOVAL PROCEDURE
WARNING
!
UNIT DAMAGE HAZARD
Be sure to wait for a minimum of 20 minutes after turning
off all power supplies and discharge the refrigerant
completely before removal.
09K/12K
1. Remove top cover
Remove the screws connecting top cover, left and
right side plate, as well as panel, to remove the top
cover.
2. Remove cable cross plate sub-assy and valve cover
Remove the screws connecting cable cross plate
sub-assy and right side plate, to remove the cable
cross plate sub-assy . Remove the screw fixing
valve cover, to remove the cover.
3. Remove panel and grille
Remove the screws fixing panel, to remove the panel.
Remove the screws connecting panel grille and panel,
loosen the clamp, to remove the panel grille.
grille
55
top cover
cable cross
plate sub-assy
valve cover
panel