Carrier 619FB Service Manual page 34

High---wall ductless split system, sizes 009 to 018
Hide thumbs Also See for 619FB:
Table of Contents

Advertisement

18K
1. Key detection point
Test9
L
D
Test5
Test12
Test No.
Test Point
Test 1
Between A and C
Test 2
Between B and C
Test 3
Between D and E
Test 4
Between F and G
Test 5
Two ends of diode D15
Test 6
Two ends of electrolytic capacitor C715
Test 7
Two ends of electrolytic capacitor C710
Test 8
Two ends of electrolytic capacitor C226
Test 9
Two ends of chip capacitor C912
Test 10
Between M to GND
Test 11
Between N to GND
Test 12
Between S and T
Test3
E
K
H
Test8
Tset7
S
T
Fig. 37 – Key detection point
Corresponding component
DC busbar electrolytic capacitor
Electrolytic capacitor of power
D15(IPM modular +15V power supply)
C715 (+12V power supply)
C226 (+3.3V power supply)
C912 (+17V power supply)
Point M of R75 to ground (signal sending
Point N of R123 to ground (signal receiving
Power supply of communication ring
Test4
Test2
F
G
J
I
Test6
M
N
Neutral and live wires
Neutral and live wires
C710 (+5V power supply)
port of ODU)
port of ODU)
34
C
Test1
B
A
Test10
Test11
Test value under normal condition
160V- - 265V
160V- - 265V
DC 180V- - 380V
DC 180V- - 380V
DC 14.5V- - 15.6V
DC 12V- - 13V
DC 5V
DC 3.3V
DC 15V- - 18V
Fluctuate between 0- - 3.3V
Fluctuate between 0- - 3.3V
DC 56V