Two lamps
D062/D063/D065
Fusing lamps
Two fusing lamps; the 280W lamp of the MT-C3 series has been
removed
Thermistors
D062/D063/D065: Contact type thermistors (center and back)
D066: One non-contact type (center) and one contact type (back)
Thermostats: D062/D063/D065 – 3, D066 - 2
Slide 67
The MT-C3.5 series also has only two lamps. This fact may have been
missing from some documentation.
D062/D063/D065: The fusing unit has spaces for three lamps, but one
of them is empty.
Part numbers of thermistors
D062/D063/D065: AW100108 (center), AW100109 (back)
D066: AW100084 (center), AW100076 (back)

Fusing Unit

Thermistor
D066
67
MT-C4 Training
Thermostat
Two
lamps