Avoid Breathing Fiber Particulates And Dust; Precautionary Measures; First Aid Procedures - Burnham V8 Series Installation & Service Instructions Manual

Seires 8v oil fired boiler
Table of Contents

Advertisement

Warning:
This product contains refractory ceramic fi bers (RCF). RCF has been classifi ed as
a possible human carcinogen. After this product is fi red, RCF may, when exposed
to extremely high temperature (>1800F), change into a known human carcinogen.
When disturbed as a result of servicing or repair, RCF becomes airborne and, if
inhaled, may be hazardous to your health.

AVOID Breathing Fiber Particulates and Dust

Precautionary Measures:

Do not remove or replace previously fi red RCF (combustion chamber insulation,
target walls, canopy gasket, fl ue cover gasket, etc.) or attempt any service or
repair work involving RCF without wearing the following protective gear:
1. A National Institute for Occupational Safety and Health (NIOSH)
approved respirator
2. Long sleeved, loose fi tting clothing
3. Gloves
4. Eye Protection
• Take steps to assure adequate ventilation.
• Wash all exposed body areas gently with soap and water after contact.
• Wash work clothes separately from other laundry and rinse washing
machine after use to avoid contaminating other clothes.
• Discard used RCF components by sealing in an air tight plastic bag.

First Aid Procedures:

• If contact with eyes: Flush with water for at least 15 minutes. Seek
immediate medical attention if irritation persists.
• If contact with skin: Wash affected area gently with soap and water.
Seek immediate medical attention if irritation persists.
• If breathing diffi culty develops: Leave the area and move to a location
with clean fresh air. Seek immediate medical attention if breathing
diffi culties persist.
• Ingestion: Do not induce vomiting. Drink plenty of water. Seek
immediate medical attention.
73