Electrical Connection - IKEA GRUNDAD Manual

Hide thumbs Also See for GRUNDAD:
Table of Contents

Advertisement

ENGLISH
Installation process must follow
the laws, ordinances, directives
and standards (electrical safety
rules and regulations, proper
recycling in accordance with the
regulations, etc.) in force in the
country of use!
• For further information on the installation
refer to the Assembly Instruction.

Electrical connection

Warning! Refer to Safety
chapters.
Warning! All electrical
connections must be made by an
authorised installer.
Electrical connection
• Before connecting, check if the nominal
voltage of the appliance, provided on the
rating plate, corresponds to the available
supply voltage. The rating plate is located
on the lower casing of the hob.
• Follow the connection diagram (it is
located on the underneath surface of the
casing of the hob).
• Use only original spare parts provided by
spare parts service.
• The appliance is not provided with a
mains cable. Buy the right one from a
• If there is no oven beneath the hob,
install a separation panel under the
appliance according to the Assembly
Instruction.
• Do not use silicon sealant between the
appliance and the worktop.
specialized dealer. Single phase or two-
phase connection requires a mains cable
of minimum 70°C temperature stability.
Cable needs mandatory end sleeves.
According to IEC regulations use for one-
phase connection: mains cable 3 x 4mm²
and for two-phase connection: mains
cable 4 x 2.5mm². Please respect specific
national regulations in the first priority.
• You must have the means for
disconnection incorporated in the fixed
wiring.
• You must have the connection and the
connecting links carried out as shown in
the connection diagram.
• The earth lead is connected to terminal
and must be longer than leads carrying
electric current.
• Secure the connecting cable with cable
clips or clamps.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

304.672.85

Table of Contents