4-4 Outdoor Display Error and Check Method

4-4-1 Test run mode and View mode
Display Option Key
KEY
KEY operation
Press once : Heating test run
K1
Press twice : Defrost test run
K2
Press once : Cooling test run
K3
Reset
K4
View mode
VIEW mode display
Number
Display contents
of press
1
Order frequency
2
Current frequency
3
Number of indoor heat exchangers
4
Out sensor
5
Discharge sensor
6
OLP sensor
7
Cond sensor
8
Current
9
Fan RPM
10
Target discharge temperature
11
EEV
12
Total indoor heat exchanger capacity
13
Protection control
14
Group address of indoor heat exchanger
15
S/W check
Samsung Electronics
All manuals and user guides at all-guides.com
7-segment display
" " " " "BLANK" "BLANK"
" " " " "BLANK" "BLANK"
" " " " "BLANK" "BLANK"
Refer to View mode display
Segment 1
Segment 2
1
Three digits
2
Three digits
3
Three digits
4
Two digits
5
Two digits
6
Two digits
7
Two digits
8
Two digits
9
Three digits
A
Three digits
B
Three digits
C
Two digits
0 : air conditioning
D
1 : heating
E
Three digits
F
7-segment display
7-segment display
Display
Segment 3
Segment 4
Two digits
One digit
Two digits
One digit
Two digits
One digit
One digit
First decimal
One digit
First decimal
One digit
First decimal
One digit
First decimal
One digit
First decimal
Two digits
One digit
Two digits
One digit
Two digits
One digit
One digit
First decimal
Protection control
Frequency state
0 : no protection
0 : Normal
control
1 : Hold
1 : freezing
2 : Down
2 : non-stop
3 : Up_limit
defrosting
4 : Sown_limit
3 : over-load
4 : discharge
Two digits
One digit
-
-
Key Switch
Key Switch
Units
Hz
Hz
Hz
°C
°C
°C
°C
C
rpm
°C
step
kW
-
-
-
-