4-1-2 Setting an indoor unit installation option
In order to check and set the indoor unit DIP option code using the wired remote controller, hold
down the
and
1
The menu will display .
Press the
button until
2
Press the
button.
The current DIP option code set in an indoor unit will be
displayed.
3
Press
button and change the page number.
The total option codes are 24digits.you can set six digits at a
time and it is distinguished by page number(0,1,2,3).
SGE1
SGE2
0
2
SEG7
SEG8
1
Drain pump
SEG13
SEG14
2
External control
SEG19
SEG20
Individual control
3
of a remote
controller
4-2
All manuals and user guides at all-guides.com
buttons at the same time for 5 seconds.
is displayed.
SGE3
Exterior temperature
RESERVED
SEG9
RESERVED
SEG15
External control output
SEG21
Heating setting
compensation
Page number
SGE4
SGE5
Central control
sensor
SEG10
SEG11
RESERVED
RESERVED
SEG16
SEG17
S-Plasma ion
Buzzer
-
-
-
-
DIP OPTION CODE
SGE6
RESERVED
SEG12
Master / Slave
SEG18
Number of hours
using filter
-
-