Cleaning The Condenser - Beko DU 9133 RA User Manual

Table of Contents

Advertisement

Available languages

Available languages

Maintenance and cleaning
If there is lint accumulation in the funnel
of the water tank, clean it under running
water.
Place the water tank into its seat.
C
If the direct water draining is
used as an option, there is no
need to empty the water tank.

6.4 Cleaning the condenser;

Hot and humid air in the condenser is cooled
with the cold air from the room. Thus, the hu-
mid air circulating in your dryer is condensed
and then pumped into the tank.
C
Clean the condenser after every
30 drying cycles or once a month.
To clean the condenser:
1. If a drying process has been carried out,
open the door of the machine and wait until
it cools down.
2. Unlock the 2 condenser locks after open-
ing the kick plate.
26 / EN
3. Pull out the condenser.
4. Clean the condenser by applying pressur-
ized water with a shower armature and wait
until the water drains.
5. Place the condenser in its housing. Fasten
the 2 locks and make sure that they are
seated securely.
6. Close the kick plate cover.
Dryer / User Manual

Advertisement

Table of Contents
loading

Table of Contents