Viewing Cable Calibration Data

Cable calibrations are performed periodically by the TAS unit so that bearings may
be computed as accurately as possible. This option allows the user to view the
results of the most recent cable calibration and causes the cable calibrations to be
performed at an accelerated rate. Cable calibrations are normally spaced at two
minute intervals, but this option causes the spacing between the end of one cable
calibration and the start of the next to be 10 seconds. An internal TAS unit variable
that displays messages on retries and/or errors is enabled. A cable calibration
sequence for a dual directional system requires about 24 seconds to complete, so a
new cable calibration summary will be displayed every 34 seconds. To view the
cable calibration data, View Data on the Cable Cal Menu (see Figure 8).
____________________________________________________________________
Honeywell International Inc.
TAS Diag for Windows User Manual
D-19
Figure 8 Cable Calibration Data Window
10609I00.ZIPCDL
KMH 880/KTA 870
P/N 700-01055-0000
Revision-
Page 15 of 18
Rev 0, October/2000