Safety Information
To obtain best results from your Furman AR-1215 or AR-2306, please be
sure to read this manual carefully.
WARNING: To reduce the risk of electrical shock, do not expose this
equipment to rain or moisture. Dangerous high voltages are present
inside the enclosure. Do not remove the covers. There are no user
serviceable parts inside. Refer servicing to qualified personnel only.
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated dangerous voltage within the
product's enclosure that may be of sufficient magnitude to
constitute a risk of electric shock.
Important Safety Instructions
Please Read Prior to Installation
1. Please read and observe all of the safety and operating instructions
before the AR-1215 or AR-2306 is operated. Retain these instructions for
future reference.
2. The AR-1215 or AR-2306 should not be used near water — for
example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet
basement, near a swimming pool, etc.
3. Do not place the AR-1215 or AR-2306 near heat sources such as
radiators, heat registers, stoves, or other appliances that produce heat.
4. Route the power cord and other cables so that they are not likely
to be walked on, tripped over, or stressed. Pay particular attention to
condition of cords and cables at plugs, and the point where they exit from
the AR-1215 or AR-2306. To prevent risk of fire or injury, damaged cords
and cables should be replaced immediately.
5. Clean the AR-1215 or AR-2306 with a damp cloth only. Do not use
solvents or abrasive cleaners. Never pour any liquid on or into the unit.
6. When left unused for a long period of time, the power cord of the
AR-1215 or AR-2306 should be unplugged from the outlet.
7. The AR-1215 or AR-2306 should be serviced by qualified service
personnel when:
a. The power supply cord or the plug has been frayed, kinked, or cut.
b. Objects have fallen or liquid has spilled into the unit.
c. The AR-1215 or AR-2306 has been exposed to rain or other
moisture.
d. The AR-1215 or AR-2306 does not appear to operate normally
or exhibits a marked change in performance.
e. The AR-1215 or AR-2306 has been dropped, or the enclosure
damaged.
8. The AR-1215 or AR-2306 requires that a safety ground be present for
proper operation. Any attempt to operate the AR-1215 or AR-2306
without a safety ground is considered improper operation and could
invalidate the warranty.
9. There are no user serviceable parts in the AR-1215 or AR-2306. Refer
servicing to qualified service personnel only.
4-9926
AC Line Voltage Regulator
MODELS AR-1215, AR-1215J, AR-2306
Instruction Sheet
Phone: 707-763-1010 • Fax: 707-763-1310
AR-Series Features
AR-1215 and AR-1215J provide nine regulated, conditioned
AC outlets—eight on the rear panel and one on the front
AR-1215 and AR-1215J input capacity is 15 A; output
capacity is 12 to 15 A
AR-2306 provides eleven regulated, conditioned AC outlets—
ten on the rear panel and one on the front
AR-2306 input capacity is 6 A ; output capacity is 5 to 6 A
Usable range for most equipment is an additional 10% above
and below the ranges shown in the table below
Extreme overvoltage or undervoltage causes instant shutdown,
protecting equipment
Extreme Voltage Shutdown indicator LED
Output In Regulation indicator
Ten-LED bargraph input voltmeter
Fast-acting user-accessible circuit breaker protects against
overload or shorts
Very low stray magnetic field leakage
On/off breaker switch
Output voltage selector switch (AR-1215J and AR-2306 only)
Compact, lightweight unit weighs only 12 lbs. (5.5 kg)
Nominal output voltages vs. input "In-regulation" ranges:
Output
Model
Accuracy
±5V
AR-1215
±5V
AR-1215J
±4V
AR-1215J
±10V
AR-2306
±10V
AR-2306
±10V
AR-2306
NOTE: The three models in the AR-Series differ in their nominal
AC output voltages. Model AR-1215 produces 120 VAC. Model
AR-1215J produces either 100 or 120 VAC. Model AR-2306
produces either 220, 230, or 240 VAC.
Where differences exist between models, information applicable to
the AR-2306 is shown in the text of this manual in brackets [ ].
FIRST: Select the Correct Voltage!
Before using your Voltage Regulator, be sure that if there is an
output voltage switch on the rear panel (just above the cord, on Mod-
els AR-1215J and AR-2306 only), it is correctly set for the AC voltage
required by your equipment. Each item of equipment that you intend
to power with the Voltage Regulator should have its required voltage
indicated on it, usually on the rear near the cord. If in doubt, consult
your dealer.
Furman Sound, Inc.
1997 South McDowell Blvd.
Petaluma, California 94954-6919 USA
www.furmansound.com
E-mail: info@furmansound.com
Voltage
In-Regulation
Setting
Range
120
97 to 141
120
97 to 141
100
80 to 122
220
174 to 264
230
181 to 276
240
190 to 288
960039-1517

Advertisement

loading

Summary of Contents for Furman AR-1215

  • Page 1 ±4V AR-1215J 80 to 122 5. Clean the AR-1215 or AR-2306 with a damp cloth only. Do not use ±10V AR-2306 174 to 264 solvents or abrasive cleaners. Never pour any liquid on or into the unit.
  • Page 2 See the Specifications on the back page for the exact voltages at which shutdown occurs. When the input Note: The AR-1215 and AR-2306 are for use with AC voltage voltage exceeds the limit, the power will cut off. It will come back on only .
  • Page 3 Furman factory or Authorized Repair Stations. This warranty corresponding to the selected voltage. On the AR-2306, there are may be cancelled by Furman at its sole discretion if the AR-1215, three scales, with the top for 220V, the middle for 230V, and the AR-1215J, or AR-2306 unit has been subjected to physical abuse bottom for 240V.
  • Page 4 Weight: 12 lbs. (5.5 kg) above 135V. AR-2306: Below 146V or above 279V (220 mode); Below 152V or above 287V (230 mode), Below 158V or above 300V The Furman AR-1215, AR-1215J and AR-2306 are made in the U.S.A. (240 mode).

This manual is also suitable for:

Ar-1215jAr-2306